Ceiling Mount Sensors
SWX-200-2 SERIES
LINE VOLTAGE
Series Downloads
Instructions
Overview
The SENSORWORX family of line voltage ceiling mount occupancy sensors provides a compact control solution capable of switching lighting loads without requiring a powerpack. SENSORWORX products utilize the latest passive infrared technology and digital signal processing techniques to provide unmatched detection performance. Additionally SENSORWORX units are available with an integrated microphone to provide overlapping passive acoustic occupancy detection for rooms with obstructions.
Basic Operations
Sensors detect movement in the infrared energy that radiates from occupants as they move within the devices field-of-view. Once occupancy is identified, the sensor’s internal relay switches power on to the connected lighting. If equipped with passive acoustic detection, the unit’s microphone is then also enabled to further enhance detection while the lights are on. An internal timer is set to keep lights on during brief periods of inactivity, and is reset every time occupancy is signaled by either the passive infrared or acoustic detection technologies. Additionally, optional daylight detection is available that will turn off controlled lighting whenever there is sufficient ambient light in the space.
Applications
Line voltage sensors are self-contained units that directly power from and switch 120/277 VAC. Typically they are used to control areas where a single sensor’s coverage area is sufficient for the entire space.
-
Private Restrooms
-
Copy Rooms
-
Vestibules
-
Small Offices
-
Conference Rooms
-
Break Rooms
-
Walk-In Closets
Features / Ceiling Mount Sensors
-
Digital Passive Infrared (PIR) Detection
-
Passive Acoustic Detection (optional)
-
360° Coverage Pattern
-
Field Changeable Lens
-
Compact Size and Matte Finish
-
Convenient Test Mode and Adjustable Time Delays
-
Electronically Timed Switching Designed for LED Fixture Control
-
Optional Ambient Light Override (Photocell)
Specifications
Physical
SIZE
4.00” Diameter x 1.25” Height
(10.16 cm x 3.17 cm)
WEIGHT
4.75 oz.
COLORS AVAILABLE
White or Black
Environmental
OPERATING TEMPERATURE
32°F to 122°F
(0°C to 50°C)
RELATIVE HUMIDITY
0-95% Non-Condensing
Indoor Use Only
ROHS COMPLIANT
Electrical
OPERATING VOLTAGE
MVOLT (120-277 VAC)
LOAD RATINGS
800W @ 120 VAC
1200W @ 227 VAC
LOAD RATINGS
1/4 HP
LOAD TYPES
Tungsten
Ballast
LED
Operation
TIME DELAYS
30 sec to 30 min
10 Minute Default
TEST MODE
5 sec
Code Compliance
Sensors can be used to meet
ASHRAE 90.1, IECC, & Title 24
energy code requirements
Coverage
Passive Infrared (PIR)
-
8 to 15 ft (2.44 to 4.57 m) mounting height recommended
-
Detection range improves when walking across beams as compared to into beams
-
Lenses can be swapped in field if necessary, contact technical support for assistance
Dual Technology (PIR/Acoustic)
-
Units with dual technology (SWX-221-2 and SWX-222-2) have overlapping acoustic detection of the complete PIR coverage area
-
A PIR event is required to initially enable acoustic detection
-
Sounds indicating occupancy reset the sensor’s time delay while non-occupant noises are filtered out
-
Occupant sounds alone will not keep lights on indefinitely, PIR motion must be periodically detected for lights to remain on for an extended time
-
After sensor time out expires, acoustic detection remains enabled for 10 seconds to enable voice reactivation of lights for additional convenience and safety
Photocell Operation
Sensors with an integrated photocell will turn lights on/off depending on the amount of ambient light detected. This operation makes them ideal for lighting near skylights or windows.
Small Motion 360°
- Best choice for detection of small motions from sitting occupants (e.g., hand motion)
- ~500 ft2 of coverage
Large Motion 360°
-
Best choice for detection of larger motion (e.g., walking)
-
~2000 ft2 of coverage
-
Longest segment of coverage pattern aligns with screw hole axis on sensor (shown as dotted line on Top View diagram below)
Wiring Diagrams
-
Sensors can be wired in parallel, although the total switching load remains the same.
-
When wired in parallel, both sensors must time out for connected lighting to turn off.
-
If wiring in an additional toggle switch for override off control, connect between the
sensor and the load.
Single Phase Wiring
2-Phase Wiring (208 VAC)
Dimming Wiring
- Dimming wires are present on daylight harvestiong models with -D option
Installation Options
Ordering Info
EXAMPLE MODEL # SWX-231-2
PRODUCT | DETECTION | COVERAGE | VOLTAGE | OPTIONS | ||||||
---|---|---|---|---|---|---|---|---|---|---|
SWX– | Ceiling Mount Sensor | 2 | PIR | 0 | Small Motion / Standard Range | 1 | MVOLT (120/277 VAC) | –2 | Standard Environment | (Blank) |
PIR + Daylight | 1 | Large Motion / Extended Range | 2 | High Humidity Environment | –HE | |||||
Dual Tech (PIR + Acoustic) | 2 | Black Cover & Lens | –BK* | |||||||
Dual Tech + DDaylight (PIR + Acoustic + Daylight) | 3 |
* Not available on units w/ Photocells
Line Voltage Ceiling Mount Sensors Popular Model Numbers
SWX-201-2 | Passive Infrared (PIR) | Small Motion 360° | Line Voltage |
SWX-202-2 | Passive Infrared (PIR) | Large Motion 360° | Line Voltage |
SWX-221-2 | Passive Dual Technology (PIR/Acoustic) | Small Motion 360° | Line Voltage |
SWX-222-2 | Passive Dual Technology (PIR/Acoustic) | Large Motion 360° | Line Voltage |
Related Products
Wall Switch Sensors
This wall switch sensor is significantly shallower than typical sensors, resulting in less crowded wall boxes.
Wide View Sensors
With five contractor friendly mounting methods, locating a sensor in a corner has never been easier.
Power Packs