Ceiling Mount Sensors

SWX-200-2 SERIES
LINE VOLTAGE

Series Downloads

Instructions

Overview

The SENSORWORX family of line voltage ceiling mount occupancy sensors provides a compact control solution capable of switching lighting loads without requiring a powerpack. SENSORWORX products utilize the latest passive infrared technology and digital signal processing techniques to provide unmatched detection performance. Additionally SENSORWORX units are available with an integrated microphone to provide overlapping passive acoustic occupancy detection for rooms with obstructions.

 

Basic Operations

Sensors detect movement in the infrared energy that radiates from occupants as they move within the devices field-of-view. Once occupancy is identified, the sensor’s internal relay switches power on to the connected lighting. If equipped with passive acoustic detection, the unit’s microphone is then also enabled to further enhance detection while the lights are on. An internal timer is set to keep lights on during brief periods of inactivity, and is reset every time occupancy is signaled by either the passive infrared or acoustic detection technologies. Additionally, optional daylight detection is available that will turn off controlled lighting whenever there is sufficient ambient light in the space.

Applications

Line voltage sensors are self-contained units that directly power from and switch 120/277 VAC. Typically they are used to control areas where a single sensor’s coverage area is sufficient for the entire space.

 

  • Private Restrooms
  • Copy Rooms
  • Vestibules
  • Small Offices
  • Conference Rooms
  • Break Rooms
  • Walk-In Closets

Features / Ceiling Mount Sensors

  • Digital Passive Infrared (PIR) Detection

  • Passive Acoustic Detection (optional)

  • 360° Coverage Pattern

  • Field Changeable Lens

  • Compact Size and Matte Finish

  • Convenient Test Mode and Adjustable Time Delays

  • Electronically Timed Switching Designed for LED Fixture Control

  • Optional Ambient Light Override (Photocell)

Specifications

Physical

SIZE
4.00” Diameter x 1.25” Height
(10.16 cm x 3.17 cm)

WEIGHT
4.75 oz.

COLORS AVAILABLE
White or Black

Environmental

OPERATING TEMPERATURE
32°F to 122°F
(0°C to 50°C)

RELATIVE HUMIDITY
0-95% Non-Condensing
Indoor Use Only

ROHS COMPLIANT

Electrical

OPERATING VOLTAGE
MVOLT (120-277 VAC)

LOAD RATINGS
800W @ 120 VAC
1200W @ 227 VAC

LOAD RATINGS
1/4 HP

LOAD TYPES
Tungsten
Ballast
LED

Operation

TIME DELAYS
30 sec to 30 min
10 Minute Default

TEST MODE
5 sec

Code Compliance

Sensors can be used to meet
ASHRAE 90.1, IECC, & Title 24
energy code requirements

Coverage

Passive Infrared (PIR)

  • 8 to 15 ft (2.44 to 4.57 m) mounting height recommended

  • Detection range improves when walking across beams as compared to into beams

  • Lenses can be swapped in field if necessary, contact technical support for assistance

Dual Technology (PIR/Acoustic)

  • Units with dual technology (SWX-221-2 and SWX-222-2) have overlapping acoustic detection of the complete PIR coverage area

  • A PIR event is required to initially enable acoustic detection

  • Sounds indicating occupancy reset the sensor’s time delay while non-occupant noises are filtered out

  • Occupant sounds alone will not keep lights on indefinitely, PIR motion must be periodically detected for lights to remain on for an extended time

  • After sensor time out expires, acoustic detection remains enabled for 10 seconds to enable voice reactivation of lights for additional convenience and safety

Photocell Operation

Sensors with an integrated photocell will turn lights on/off depending on the amount of ambient light detected. This operation makes them ideal for lighting near skylights or windows.

Small Motion 360°

  • Best choice for detection of small motions from sitting occupants (e.g., hand motion)
  • ~500 ftof coverage

 

Large Motion 360°

  • Best choice for detection of larger motion (e.g., walking)

  • ~2000 ft2 of coverage

  • Longest segment of coverage pattern aligns with screw hole axis on sensor (shown as dotted line on Top View diagram below)

Wiring Diagrams

  • Sensors can be wired in parallel, although the total switching load remains the same.

  • When wired in parallel, both sensors must time out for connected lighting to turn off.

  • If wiring in an additional toggle switch for override off control, connect between the
    sensor and the load.

Single Phase Wiring

2-Phase Wiring (208 VAC)

Dimming Wiring

  • Dimming wires are present on daylight harvestiong models with -D option

Installation Options

Ordering Info

EXAMPLE MODEL # SWX-231-2
PRODUCTDETECTIONCOVERAGEVOLTAGEOPTIONS
SWX–Ceiling Mount Sensor2PIR0Small Motion / Standard Range1MVOLT (120/277 VAC)–2Standard Environment(Blank)
PIR + Daylight1Large Motion / Extended Range2High Humidity Environment–HE
Dual Tech (PIR + Acoustic)2Black Cover & Lens–BK*
Dual Tech + DDaylight (PIR + Acoustic + Daylight)3

* Not available on units w/ Photocells

Line Voltage Ceiling Mount Sensors Popular Model Numbers

SWX-201-2Passive Infrared (PIR) | Small Motion 360° | Line Voltage
SWX-202-2Passive Infrared (PIR) | Large Motion 360° | Line Voltage
SWX-221-2Passive Dual Technology (PIR/Acoustic) | Small Motion 360° | Line Voltage
SWX-222-2Passive Dual Technology (PIR/Acoustic) | Large Motion 360° | Line Voltage

Related Products

Wall Switch Sensors

This wall switch sensor is significantly shallower than typical sensors, resulting in less crowded wall boxes.

Wide View Sensors

With five contractor friendly mounting methods, locating a sensor in a corner has never been easier.

Power Packs

Mounting snaps and an optional low voltage wiring chamber make this power pack a breeze to install.

Design by DZYNR   |  ©2024 BLP Technologies, Inc. All Rights Reserved.