Lighting Controls — Wired | Wireless

Wide View & Hallway Sensors

SWX-400-1 SERIES
LOW VOLTAGE

Series Downloads

Instructions

Overview

SENSORWORX® wide view and hallway occupancy sensors enable mounting to a wall, corner, junction box, or conduit. This flexibility reduces contractor installation time and provides a secure and clean finished appearance. SENSORWORX products utilize the latest passive infrared technology and digital signal processing techniques to provide unmatched detection performance. Additionally, these SENSORWORX units are available with an integrated microphone to provide overlapping passive acoustic occupancy detection for rooms with obstructions or where occupant motion will be limited.

 

Basic Operations

Sensors detect movement in the infrared energy that radiates from occupants as they move within the devices field-of-view. Once occupancy is identified the sensor signals a connected power/relay pack to switch on the connected lighting. If equipped with passive dual (PIR/Acoustic) technology, the unit’s microphone is then also enabled to further enhance detection while the lights are on. An internal timer is set to keep lights on during brief periods of inactivity, and is reset every time occupancy is signaled by either the passive infrared or acoustic detection technologies. Additionally, optional daylight detection is available that will turn off controlled lighting whenever there is sufficient ambient light in the space.

Applications

A single sensor may provide sufficient coverage in many spaces, however, multiple low voltage sensors can be easily wired together to provide improved coverage for large or irregular shaped spaces.

 
  • Classrooms
  • Open Areas
  • Large Offices
  • Conference Rooms
  • Hallways/Corridors

Features / Wide View & Hallway Sensors

  • Digital Passive Infrared (PIR) Detection

  • Passive Acoustic Detection (Optional)

  • Wide View (120°) or Hallway (Long Range) Coverage Pattern Options

  • Compact Size and Matte Finish

  • Five Contractor Friendly Mounting Methods

  • Mounting Nipple Attachment with Integrated Hole Saw

  • Convenient Test Mode and Adjustable Time Delays

  • Optional Ambient Light Override (Photocell)

Specifications

Physical

SIZE
2.875” H x 2.75” W x 3.25”D
(7.30 x 6.98 x 8.25 cm)

WEIGHT
4.75 oz.

COLOR
White

Environmental

OPERATING TEMP
32°F to 122°F
(0°C to 50°C)

RELATIVE HUMIDITY
0-95% Non-Condensing, Indoor Use Only

ROHS COMPLIANT

Electrical

OPERATING VOLTAGE
12-24 VAC/VDC

CURRENT DRAW
5mA (PIR Models)
10mA (Dual Tech. Models)
12mA (Dual Tech. w/ Photocell Units)

OUTPUT
Logic High VDC (Occupied Mode)

RECOMMENDED POWER PACKS
SENSORWORX (e.g., SWX-900)

ISOLATED RELAY RATING
1A @ 30 VDC/VAC

Operation

TIME DELAYS
0 sec. to 30 min.
10 Minute Default

TEST MODE
5 sec.

Coverage Patterns

WIDE VIEW 120°

PASSIVE INFRARED (PIR)

  • Small motion (e.g., hand movements) detection up to 40 ft (12.19 m)
  • Large motion (e.g., walking) detection up to 70 ft (21.34 m)
  • Designed for 8 to 12 ft (2.44 to 3.66 m) high mounting

Diagram reflects sensor in first position. Adjust angle downward if mounting above 10 feet or to decrease gap directly under sensor.

HALLWAY (LONG RANGE)

  • Designed for 8 to 12 ft (2.44 to 3.66 m) high mounting
  • Large motion (e.g., walking) detection up to 100 ft (30.48 m)
  • Detection occurs sooner when crossing coverage beams upon entry to a hallway as opposed to entering from the end and walking directly at the sensor

DUAL TECHNOLOGY (PIR/ACOUSTIC)

  • Units with dual technology (SWX-421-1 and SWX-431-1) have overlapping acoustic detection of the complete PIR coverage area.
  • A PIR event is required to initially enable acoustic detection
  • Sounds indicating occupancy reset the sensor’s time delay while non-occupant noises are filtered out
  • Occupant sounds alone will not keep lights on indefinitely, PIR motion must be periodically detected for lights to remain on for an extended time
  • After sensor time out expires, acoustic detection remains enabled for 10 seconds to enable voice reactivation of lights for additional convenience and safety
  • Not available on units with Hallway (Long Range) lens

AMBIENT LIGHT OVERRIDE (PHOTOCELL) OPERATION

Sensors with an integrated photocell will turn lights on/off depending on the amount of ambient light detected. This operation makes them ideal for lighting near skylights or windows.

Wiring Diagrams

Standard Wiring

SENSOR CONTROL OF SEPARATE OCCUPANCY & PHOTOCELL ZONES

  • During occupied state, photocell output (blue wire) will turn lights off if ambient light level surpasses threshold and back on if level drops
  • Also configurable to prevent lights from initially turning on, but not to turn them off once lights are on
  • Configurable ambient light threshold levels or auto-selection

SENSOR AUXILIARY RELAY INTERFACE TO BMS

  • The auxiliary output relay (model option -AR) is designed to interface with many types of BMS, VAV units, and relay panels
  • Operation of relay (brown wires) is configurable:
    • By default the relay latches closed when occupancy is detected (white wire goes high)
    • Relay can be configured to alternatively follow the occupancy + photocell (blue wire) output (if unit is equipped)
    • Relay polarity (open vs closed) can also be reversed

Installation Options

Ordering Info

EXAMPLE MODEL # SWX-421-1
PRODUCTDETECTIONCOVERAGEVOLTAGEOPTIONS
SWX–Wide View Sensor4PIR0120° Wide View1Low Voltage–1Isolated Auxiliary Relay–AR
PIR + Daylight1Hallway (Long Range)*2
Dual Tech (PIR + Acoustic)2
Dual Tech + Daylight (PIR + Acoustic + Daylight)3

* Dual Tech detection options not available for units with the Hallway coverage option.

Wide View Sensors Popular Model Numbers

SWX-401-1Passive Infrared (PIR) | 120° Wide View | Low Voltage
SWX-421-1Passive Dual Technology (PIR/Acoustic) | 120° Wide View° | Low Voltage
SWX-402-1Passive Infrared (PIR) | Hallway (Long Range) | Low Voltage

Related Products

Wall Switch Sensors

This wall switch sensor is significantly shallower than typical sensors, resulting in less crowded wall boxes.

Ceiling Sensors

This sensor’s chase nipple attachment makes surface mounting to a finished ceiling simple and secure.

Power Packs

Mounting snaps and an optional low voltage wiring chamber make this power pack a breeze to install.

Design by DZYNR   |  ©2024 BLP Technologies, Inc. All Rights Reserved.